Features
- Voltage up 1500 V DC & 1000 V AC
- Current up to 2 A DC & AC
- Resistance up to 20 MΩ
- Diode/Continuity Test
- CAT IV 1000 V safety rating
- IP67 rated
- Magne-Grip holster w/magnetic hanging strap
- Drop-resistant housing and PCB mounting
- Includes high voltage test leads w/threaded alligator clips
The Amprobe HD110C heavy duty digital multimeter is designed for professional use in harsh environments. This
Amprobe multimeter is unusually rugged and reliable in everyday heavy use applications. The Amprobe HD110C
multimeter is made using waterproof construction to prevent dirt, grime, and moisture from entering the case
and causing inaccurate readings or damaging shorts.
The Amprobe HD110C multimeter is built of tough, fire retardant thermoplastic resistant to grease and chemical
spills. All sensitive components are shock-mounted for a drop resistance to at least eight feet.
The heavy duty Amprobe HD110C multimeter has an extended voltage measurement capability of 1500 V DC and 1000
V AC, unmatched by any other line of digital multimeters. The extended voltage ranges can withstand transients
up to 12 kV.
The Amprobe HD110C multimeter ships complete with:
Test leads (TL1500)
Battery
Hex wrench in holster
Magne-Grip flex strip
Manual
The Amprobe HD110C Heavy Duty Multimeter Specifications
Function
Range
Accuracy
DC Volts
200 mV, 2 V, 20 V, 1500 V
±(0.1% rdg + 2 dgt)
Resolution
0.1 mV
Input Impedance
10 MΩ
Transient Protection
12 kV impulse (1.2 µS/50 µS) based on EN
61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should
not be used in installations where transients exceed 12 kV.
OL Protection
1500 V DC or 1000 V AC RMS
AC Volts (45 Hz to 2 kHz)
200 mV to 200 V(45 to 500 Hz)
200 mV to 200 V (500 Hz - 2 kHz)
1000 V (50 to 60 Hz)
1000 V (60 to 500 Hz)
±(0.8% rdg + 4 dgt)
±(1.5% rdg + 5 dgt)
±(0.8% rdg + 4 dgt)
±(1.5% rdg + 5 dgt)
Resolution
0.1 mV
Input Impedance
10 MΩ
OL Protection
1500 V DC or 1000 V AC RMS
Transient Protection
12 kV impulse (1.2 µS/50 µS) based on EN
61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should
not be used in installations where transients exceed 12 kV.
DC Current
200 µA to 20 mA
200 mA to 2 A
±(0.5% rdg + 2 dgt)
±(1.0% rdg + 2 dgt)
Resolution
0.1 µA
Burden voltage
250 mV max. (1 mV/1 µA on 200 µA range)
(100 mV/a mA on 2 mA range)
(10 mV/ 1 mA on 20 mA range)
(1.5 mV/1 mA on 200 mA range)
(500 mV/1 A on 2 A range)
OL Protection
A Input (F 2 A/1500 V, size 8 x 65 mm IR fast blow ceramic)
AC Current (45 Hz to 1 kHz)
200 µA to 20 mA
200 mA to 2 A
±(0.8% rdg + 4 dgt)
±(1.2% rdg + 4 dgt)
Resolution
0.1 µA
Burden voltage
250 mV max. (1 V on 2 A range)
OL Protection
Same as DC current
Resistance
200 Ω
2 kΩ to 200 kΩ
2 MΩ
20 MΩ
±(0.5% rdg + 4 dgt)
±(0.3% rdg + 2 dgt)
±(1.0% rdg + 4 dgt)
±(2.0% rdg + 4 dgt)
Resolution
0.1 Ω
Overload Protection
1500 V DC or 1000 V AC RMS
Open circuit voltage
200 Ω rangeall other ranges
3.0 V DC typical0.3 V DC typical
Diode/Continuity test
Test current
1 m A DC typical
Test/Open Circuit Voltage
3.0 V DC typical
Diode Accuracy
±(1.5% rdg + 2 dgt)
Continuity audible threshold
< 50 Ω ± 25 Ω
Response time
< 100 msec
Overload protection
1500 V DC or 1000 V AC RMS