Features
- Voltage up 1500 V DC & 1000 V AC
- Current up to 2 A DC & AC
- Resistance up to 40 MΩ
- Capacitance up to 400 µF
- Temperature: -4°F to 2372°F (-20°C - 1300°C)
- True RMS
- CAT IV 1000 V safety rating
- IP67 rated
- Temperature, Frequency and Capacitance measurement
- Drop-resistant housing and PCB mounting
- 10,000 count resolution w/bar graph
- Magne-Grip holster w/magnetic hanging strap
The heavy duty Amprobe HD160C multimeter is a professional-grade digital multimeter designed for use in harsh
environments. The Amprobe HD160C is IP67 rated to prevent dirt, grime, and moisture from entering the case and
causing inaccurate readings or damaging shorts. Additionally, the housing is built of tough, fire retardant
thermoplastic resistant to grease and chemical spills. All sensitive components are shock-mounted for a drop
resistance to at least eight feet. These protective features make this Amprobe multimeter unusually rugged and
reliable in everyday heavy use applications.
The Amprobe HD160C multimeter has an extended voltage measurement capability of 1500 V DC and 1000 V AC which
is unmatched by any other line of digital multimeters. This Amprobe multimeter also accurately measures AC/DC
current, temperature, frequency, and capacitance. All measured values are shown on the HD160C's high resolution
LCD display with bargraph and Digi-Glo bright backlight. An audible continuity test is also included. The
Amprobe HD160C multimeter has a CAT IV 1000 V safety rating.
The Amprobe HD110C heavy duty digital multimeter ships complete with:
Test leads(TL1500)
Battery
Hex wrench in holster
Holster w/Magne-Grip strap
Type K Thermocouple probe(TP255)
Temperature adapter(TA-1A)
Manual
Amprobe HD160C Multimeter Specifications
Function
Range
Accuracy
DC Volts
1000 mV, 10 V, 100 V, 1500 V
±(0.1% rdg + 5 dgt)
Resolution
0.1 mV in 1000 mV range
Input Impedance
10 MΩ
CMRR
>120 dB up to 1500 V DC
NMRR
>60 dB at 50 or 60 Hz
OL Protection
1500 V DC or 1000 V AC RMS
AC Volts True RMS
1000 mV (45 Hz to 400 Hz)
10 V, 100 V (45 Hz to 500 Hz)
10 V, 100 V (500 Hz to 2 kHz)
1000 V (45 Hz to 1 kHz)
±(1.2% rdg + 10 dgt)
±(1.2% rdg + 10 dgt)
±(2.0% rdg + 10 dgt)
±(2.0% rdg + 10 dgt)
Resolution
0.1 mV in 1000 mV range
Input Impedance
10 MΩ
Conversion type
True rms, AC coupled 5 % to 100 % of range
Crest factor
≤ 3
OL Protection
1500 V DC or 1000 V AC RMS
DC Current
100 µA
1000 µA to 400 mA
2 A
±(0.5% rdg + 10 dgt)
±(0.5% rdg + 5 dgt)
±(1.5% rdg + 10 dgt)
Resolution
0.01 µA in 100 µA range
Input protection
2 A/1500 V fast blow ceramic fuse
Burden voltage
µA range of 1 mV/a µA, mA range of 10 mV/1 mA, 2 A range of 500 mV/1 A, 500 mV max.
OL Protection
A Input (F 2 A/1500 V, size 8 x 65 mm IR fast blow ceramic)
AC Current True RMS
100 µA to 100 mA
400 mA
2 A
±(1.5% rdg + 10 dgt)
±(2.0% rdg + 10 dgt)
±(2.5% rdg + 10 dgt)
Resolution
0.01 µA in 100 µA range
Burden voltage
see DC current
Conversion type
True RMS AC coupled 10 to 100% of range
Crest factor
≤ 3
OL Protection
See DC current
Resistance
1000 Ω to 1000 kΩ
10 MΩ
40 MΩ
±(0.5% rdg + 8 dgt)
±(1.0% rdg + 10 dgt)
±(2.0% rdg + 10 dgt)
Resolution
0.1 Ω in 1000 Ω range
Overload Protection
1500 V DC or 1000 V AC RMS
Continuity test
Audible indication
Less than 40 Ω
Response time
100 ms
Overload protection
1500 V DC or 1000 V AC RMS
Capacitance
40 nF, 400 µF
400 nF to 40 µF
±(3.0% rdg + 10 dgt)
±(3.0% rdg + 5 dgt)
Resolution
0.01 nF
Test voltage
< 1 V
Test frequency
1.3 Hz on 40 nF to 400 µF ranges; 0.7 Hz on 400 µF range
Overload protection
1500 V DC or 1000 V AC RMS
Temperature
-20°C ~ 10°C
10°C ~ 200°C
200°C ~ 1300°C
-4°F ~ 50°F
50 °F ~ 400°F
400°F ~ 2372°F
±(2.0% rdg + 4°C)
±(1.0% rdg + 3°C)
±(2.0% rdg + 2°C)
±(2.0% rdg + 8°F)
±(1.0% rdg + 6°F)
±(2.0% rdg + 4°F)
Resolution
1°C, 1°F
Overload protection
1500 V DC or 1000 V AC RMS