معرفی
جزيیات
خانه/ اتوماسیون صنعتی/ کنترلر/ پی ال سی و دی سی اس/ Omron/ CP1E-N30DR-A | Omron | CP1E CPU Unit Hardware

CP1E-N30DR-A | Omron | CP1E CPU Unit Hardware
به دلیل سفارشی بودن کالاها و نوسانات قیمت ارز، لطفا برای اطلاع از قیمت بروز کالا استعلام بگیرید.
ویژگی ها / Specifications
| .red {color | #F00;}.red {color #F00;}.red1 { color #F00;}Estimated Lead Time Usually ships in 1 - 10 working days.Manufacturer Omron CP1E-N30DR-ACP-series CP1E CPU UnitsCP1ECost-effective CP1E with Enhanced Expandability for Analog and Temperature ControlThe CP1E Package PLCs Economy, Easy, and EfficientThe E-type Basic CPU Units provide cost performance and easy application with only basic functionality.The N-type Application CPU Units support Programmable Terminal connection, position control, and inverter connectionProgramming, setting, and monitoring with CX-Programmer.Easy connection with computers using commercially available USB cablesExpansion I/O Units can be used to increase the I/O capacity of a CPU Unit (for CPU Units with 30 or 40 I/Opoints).Expansion Units can be used to add analog I/O or temperature inputs to a CPU Unit with 30 or 40 I/O points.Quick-response inputsInput interruptsExtensive high-speed counter functionality.Versatile pulse control (Models with transistor outputs only).Execution of origin searches and origin returns using instructions (Models with transistor outputs only).weight 600g maxPWM output function (Models with transistor outputs only).Changing settings with the analog adjusters.Built-in RS-232C port on N-type CPU Units.A Serial Option Board can be added to N-type CPU Units with 30 or 40 I/O points.AC power supply modelsEnclosure Mounted in a panelTerminal block Fixed (not removable)Terminal screw size M3Applicable standards EC DirectiveGrounding method Ground to 100 ? or lessSupply voltage 100 to 240 VAC 50/60 HzOperating voltage range 85 to 264 VACInrush current 120 VAC, 20 A for 8 ms max. for cold start at room temperature, 240 VAC, 40 A for 8 ms max. for cold start at room temperature.Insulation resistance 20 M? min. (at 500 VDC) between the external AC terminals and GR terminals.Altitude 2,000 m max.Pollution degree 2 or less Conforms to JIS B3502 and IEC 61131-2.Noise resistance 2 kV on power supply line (Conforms to IEC61000-4-4.)Overvoltage category Category II Conforms to JIS B3502 and IEC 61131-2EMC Immunity Level Zone BVibration resistance Conforms to JIS 60068-2-6.5 to 8.4 Hz with 3.5-mm amplitude8.4 to 150 Hz, Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total)Shock resistance Conforms to JIS 60068-2-27, 147 m/s2, 3 times in X, Y, and Z directionsShipping weight 2 Kg |














