ویژگی ها / Specifications
| Brand | Yokogawa |
| Model | EJA110E Differential Pressure Transmitter |
| Capsule | Monel |
| Condition | New & Original in Factory Packing |
| Certificate | DEKRA 11ATEX0228 X |
| Capsule gasket | PTFE Teflon |
| Retention time | one minute |
| Electrical data | Ui=30 V, Ii=200 mA, Pi=0.9 W, Ci=27.6 nF, Li=0 µH |
| Vent/Drain plug | Monel |
| Factory Warranty | 12 Months |
| Degree of protection | IP66/IP67 |
| Amb. Temp. for EPL Db | –30 to 60°C(8) |
| Amb. Temp. (Tamb) for EPL Ga | –50 to 60°C (–58 to 140°F) |
| Maximum Process Temp. (Tp) for EPL Ga | 120°C |
| Pressure test/ Leak test certificate(11) T12 Test Pressure | 16 MPa(2300 psi) |
| Wetted parts material(2) B# Cover flange and process connector | Monel equivalent(3) |
Description / توضیحات
EJA110E features include:
0.055% Accuracy (0.04% Accuracy optional)
0.1% Stability per 10 years
90 ms Response Time
Exida and TUV SIL 2 / SIL3 Certified
MWP 2,300 psi (MWP 3,600 psi option)
Local Parameter Setting (LPS)
Model and Suffix Codes
Model EJA110E Differential pressure transmitter
Output signal -J 4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)(1)
Measurement span (capsule) H 5 to 500 kPa (20 to 2000 inH2O)
Process connections *5 without process connector (1/4 NPT female on the cover flanges)
Bolts and nuts material G 316L SST
Installation -7 Vertical piping, left side high pressure, and process connection downside
Amplifier housing 2 ASTM CF-8M stainless steel(4)
Electrical connection D M20 female, two electrical connections and a SUS316 blind plug
Integral indicator D Digital indicator(5)
Mounting bracket K 316 SST or SCS14A 2-inch pipe mounting, L type (for vertical piping)
ATEX KS21 ATEX Intrinsically safe Approval(6)(7)
Applicable Standard: EN 60079-0:2012/A11:2013, EN 60079-11:2012, EN 60079-26:2007
II 1G, 2D Ex ia IIC T4 Ga, Ex ia IIIC T85°C T100°C T120°C Db
Max. surface Temp. for EPL Db: T85°C (Tp: 80°C), T100°C (Tp: 100°C), T120°C (Tp: 120°C)
Material certificate(9) M01 Cover flange(10)
Nitrogen(N2) Gas(12)
Calibration units(13) D3 bar calibration (bar unit)
The “*” marks indicate the most typical selection for each specification.
HART 5 or HART 7 is selectable. Specify upon ordering
Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user’s process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.
Indicated material is equivalent to ASTM M35-2.
Not applicable for electrical connection code 0, 5, 7 and 9.
Not applicable for output signal code G.
Applicable for Electrical connection code 2, 4, 7, 9, C and D.
Not applicable for output signal code Q.
Lower limit of ambient temperature is –15°C (5°F) when option code HE is specified.
Material traceability certification, per EN 10204 3.1B.
Applicable for process connections codes 0 and 5.
The unit on the certificate is always Pa unit regardless of selection of option code D1, D3 or D4.
Pure nitrogen gas is used for oil-prohibited use (option codes K1, K2, K5, and K6).
The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option codes D1, D3, and D4.
Attachment / فایل ضمیمه
General Specifications: EJA110E
General Specifications: EJA110E High Damping Option
General Specifications: EJA-E Series FOUNDATION Fieldbus Communication
General Specifications: EJA-E Series HART Communication
General Specifications: EJA-E Series PROFIBUS PA Communication
DPharp BRAIN Communication Type
Installation Manual: EJA-E and EJX-A Series
User's Manual: DPharp PROFIBUS PA (EJXxxxA, EJAxxxE)
User's Manual: EJA-E Series BRAIN Communication
User's Manual: EJA-E Series FOUNDATION Fieldbus Communication