معرفی
جزيیات
خانه/ ترانسمیتر/ ترانسمیتر فشار/ Yokogawa/ EJA110E-JMS3J-313DA/D3 | Yokogawa EJA110E Differential Pressure Transmitter

EJA110E-JMS3J-313DA/D3 | Yokogawa EJA110E Differential Pressure Transmitter
به دلیل سفارشی بودن کالاها و نوسانات قیمت ارز، لطفا برای اطلاع از قیمت بروز کالا استعلام بگیرید.
ویژگی ها / Specifications
| Model | EJA110E - Differential pressure transmitter |
| Capsule | Hastelloy C-2764 (Diaphragm); F316L SST, 316L SST (Others) |
| Installation | -3 |
| Output signal | -J - 4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)? |
| Capsule gasket | Teflon-coated 316L SST |
| Vent/Drain plug | 316 SST |
| Mounting bracket | A |
| Amplifier housing | 1 - Cast aluminium alloy |
| Calibration Unit6 | /D3 - bar calibration (bar unit) |
| Integral indicator | D - Digital indicator5 |
| Process connections | 3 - with 1/4 NPT female process connector |
| Electrical connection | 3 |
| Wetted parts material? | S |
| Bolts and nuts material | J - B7 carbon steel |
| Measurement span (capsule) | M - 1 to 100 kPa (4 to 400 inH2O) |
| Cover flange and process connector | ASTM CF-8M? |
Description / توضیحات
Model and Suffix Codes
NOTE:
The " * " marks indicate the most typical selection for each specification.
HART 5 or HART 7 is selectable. Specify upon ordering.
Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user s process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150?C [302?F] or above). Contact Yokogawa for detailed information of the wetted parts material.
Cast version of 316 SST. Equivalent to SCS14A.
Hastelloy C-276 or ASTM N10276.
Not applicable for output signal code G.
The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option codes D1, D3, and D4.
Attachment / فایل ضمیمه
General Specifications: EJA110E
General Specifications: EJA110E High Damping Option
General Specifications: EJA-E Series FOUNDATION Fieldbus Communication
General Specifications: EJA-E Series HART Communication
General Specifications: EJA-E Series PROFIBUS PA Communication
DPharp BRAIN Communication Type
Installation Manual: EJA-E and EJX-A Series
User's Manual: DPharp PROFIBUS PA (EJXxxxA, EJAxxxE)
User's Manual: EJA-E Series BRAIN Communication
User's Manual: EJA-E Series FOUNDATION Fieldbus Communication