معرفی
جزيیات
خانه/ ترانسمیتر/ ترانسمیتر فشار/ Yokogawa/ EJA110E-JMS4G-912EB/KS21/X2/A | Yokogawa EJA110E Differential Pressure Transmitter

EJA110E-JMS4G-912EB/KS21/X2/A | Yokogawa EJA110E Differential Pressure Transmitter
به دلیل سفارشی بودن کالاها و نوسانات قیمت ارز، لطفا برای اطلاع از قیمت بروز کالا استعلام بگیرید.
ویژگی ها / Specifications
| Model | EJA110E - Differential pressure transmitter |
| Capsule | Hastelloy C-2764 (Diaphragm); F316L SST, 316L SST (Others) |
| Certificate | DEKRA 11ATEX0228 X |
| Installation | -9 - Horizontal piping and left side high pressure |
| Output signal | -J - 4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)? |
| Capsule gasket | Teflon-coated 316L SST |
| Coating change | Anti-corrosion coating10, 11 |
| Electrical data | Ui=30 V, Ii=200 mA, Pi=0.9 W, Ci=27.6 nF, Li=0 ?H |
| Vent/Drain plug | 316 SST |
| Mounting bracket | B - 304 SST 2-inch pipe mounting, flat type (for horizontal piping) |
| Allowable current | Max. 6000 A (1?40 ?s), Repeating 1000 A (1?40 ?s) 100 times |
| Amplifier housing | 1 - Cast aluminum alloy |
| Integral indicator | E - Digital indicator with the range setting switch (push button)6 |
| Process connections | 4 - with 1/2 NPT female process connector |
| Applicable Standards | IEC 61000-4-4, IEC 61000-4-5 |
| Degree of protection | IP66/IP67 |
| Amb. Temp. for EPL Db | ? to 60?C9 |
| Electrical connection | 2 - 1/2 NPT female, two electrical connections without blind plugs plug5 |
| Wetted parts material? | S |
| Bolts and nuts material | G - 316L SST |
| Measurement span (capsule) | M - 1 to 100 kPa (4 to 400 inH2O) |
| Amb. Temp. (Tamb) for EPL Ga | ? to 60?C (? to 140?F) |
| Transmitter power supply voltage | 10.5 to 32 V DC (10.5 to 30 V DC for intrinsically safe type.) |
| Cover flange and process connector | ASTM CF-8M? |
| Maximum Process Temp. (Tp) for EPL Ga | 120?C |
Description / توضیحات
Model and Suffix Codes
Optional Codes:
/KS21 - ATEX
ATEX Intrinsically safe Approval7,8
Applicable Standard: EN 60079-0:2012/A11:2013, EN 60079-11:2012, EN 60079-26:2007
II 1G, 2D Ex ia IIC T4 Ga, Ex ia IIIC T85?C T100?C T120?C Db
Max. surface Temp. for EPL Db: T85?C (Tp: 80?C), T100?C (Tp: 100?C), T120?C (Tp: 120?C)
/X2 - Painting
/A - Lightning protector
NOTE:
The " * " marks indicate the most typical selection for each specification.
HART 5 or HART 7 is selectable. Specify upon ordering.
Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user s process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150?C [302?F] or above). Contact Yokogawa for detailed information of the wetted parts material.
Cast version of 316 SST. Equivalent to SCS14A.
Hastelloy C-276 or ASTM N10276.
Not applicable for output signal code G.
Not applicable for output signal code F.
Applicable for Electrical connection code 2, 4, 7, 9, C and D.
Not applicable for output signal code Q.
Lower limit of ambient temperature is ??C (5?F) when option code HE is specified.
Not applicable for amplifier housing code 2 and 3.
Not applicable with color change option.
Attachment / فایل ضمیمه
General Specifications: EJA110E
General Specifications: EJA110E High Damping Option
General Specifications: EJA-E Series FOUNDATION Fieldbus Communication
General Specifications: EJA-E Series HART Communication
General Specifications: EJA-E Series PROFIBUS PA Communication
DPharp BRAIN Communication Type
Installation Manual: EJA-E and EJX-A Series
User's Manual: DPharp PROFIBUS PA (EJXxxxA, EJAxxxE)
User's Manual: EJA-E Series BRAIN Communication
User's Manual: EJA-E Series FOUNDATION Fieldbus Communication