معرفی

جزيیات

18314

EJA110E-JMS4G-912EB/KS21/X2/A | Yokogawa EJA110E Differential Pressure Transmitter

برند :

Yokogawa

پارت نامبر :

EJA110E-JMS4G-912EB/KS21/X2/A

زمان تحویل:

16 هفته

به دلیل سفارشی بودن کالاها و نوسانات قیمت ارز، لطفا برای اطلاع از قیمت بروز کالا استعلام بگیرید.

ویژگی ها / Specifications


ModelEJA110E - Differential pressure transmitter
CapsuleHastelloy C-2764 (Diaphragm); F316L SST, 316L SST (Others)
CertificateDEKRA 11ATEX0228 X
Installation-9 - Horizontal piping and left side high pressure
Output signal-J - 4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)?
Capsule gasketTeflon-coated 316L SST
Coating changeAnti-corrosion coating10, 11
Electrical dataUi=30 V, Ii=200 mA, Pi=0.9 W, Ci=27.6 nF, Li=0 ?H
Vent/Drain plug316 SST
Mounting bracketB - 304 SST 2-inch pipe mounting, flat type (for horizontal piping)
Allowable currentMax. 6000 A (1?40 ?s), Repeating 1000 A (1?40 ?s) 100 times
Amplifier housing1 - Cast aluminum alloy
Integral indicatorE - Digital indicator with the range setting switch (push button)6
Process connections4 - with 1/2 NPT female process connector
Applicable StandardsIEC 61000-4-4, IEC 61000-4-5
Degree of protectionIP66/IP67
Amb. Temp. for EPL Db? to 60?C9
Electrical connection2 - 1/2 NPT female, two electrical connections without blind plugs plug5
Wetted parts material?S
Bolts and nuts materialG - 316L SST
Measurement span (capsule)M - 1 to 100 kPa (4 to 400 inH2O)
Amb. Temp. (Tamb) for EPL Ga? to 60?C (? to 140?F)
Transmitter power supply voltage10.5 to 32 V DC (10.5 to 30 V DC for intrinsically safe type.)
Cover flange and process connectorASTM CF-8M?
Maximum Process Temp. (Tp) for EPL Ga120?C

Description / توضیحات


Model and Suffix Codes Optional Codes: /KS21 - ATEX ATEX Intrinsically safe Approval7,8 Applicable Standard: EN 60079-0:2012/A11:2013, EN 60079-11:2012, EN 60079-26:2007 II 1G, 2D Ex ia IIC T4 Ga, Ex ia IIIC T85?C T100?C T120?C Db Max. surface Temp. for EPL Db: T85?C (Tp: 80?C), T100?C (Tp: 100?C), T120?C (Tp: 120?C) /X2 - Painting /A - Lightning protector NOTE: The " * " marks indicate the most typical selection for each specification. HART 5 or HART 7 is selectable. Specify upon ordering. Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user s process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150?C [302?F] or above). Contact Yokogawa for detailed information of the wetted parts material. Cast version of 316 SST. Equivalent to SCS14A. Hastelloy C-276 or ASTM N10276. Not applicable for output signal code G. Not applicable for output signal code F. Applicable for Electrical connection code 2, 4, 7, 9, C and D. Not applicable for output signal code Q. Lower limit of ambient temperature is ??C (5?F) when option code HE is specified. Not applicable for amplifier housing code 2 and 3. Not applicable with color change option.