معرفی

جزيیات

8278

EJA118E-FHSCG-919DN-WA43C1SW00-CA25/KF25/M2W/T58 | Yokogawa EJA118E Diaphragm Sealed Differential Pressure Transmitter

برند :

Yokogawa

پارت نامبر :

EJA118E-FHSCG-919DN-WA43C1SW00-CA25/KF25/M2W/T58

زمان تحویل:

16 هفته

به دلیل سفارشی بودن کالاها و نوسانات قیمت ارز، لطفا برای اطلاع از قیمت بروز کالا استعلام بگیرید.

ویژگی ها / Specifications


ModelEJA118E Diaphragm Sealed Differential Pressure Transmitter
Others316L SST
Material-
ConditionNew & Original in Factory Packing
Retention timeone minute
Factory Warranty12 Months
Vent/Drain plugs-
Ambient temperature10 to 60°C
Process temperature10 to 310°C
Flushing connection ring(6) *0 RingNone
Wetted parts material(5) SW Diaphragm316L SST

Description / توضیحات


Description The EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family. Released in 2012, it combines the ruggedness and success of the work-horse EJA-E series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa. The EJA118E is a Differential Pressure Transmitter with remote diaphragm seals. EJA118E features include: ±0.2% Accuracy 200 ms Response Time Exida and TUV SIL2 / SIL3 Certified Local Parameter Setting (LPS) 10-segment Signal Characterizer Active Capillary Fill Fluid Density Compensation Model and Suffix Codes Model EJA118E Diaphragm sealed differential pressure transmitter Output signal -F Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C31T02-01EN) Measurement span (capsule) H 25 to 500 kPa (100 to 2000 inH2O) S Always S C Always C Cover flange bolts and nuts material G 316L SST Installation -9 Horizontal piping type and left side high pressure Amplifier housing 1 Cast aluminum alloy Electrical connection 9 M20 female, two electrical connections with a blind plug(1) Integral indicator D Digital indicator(2) Mounting bracket N None Process connection style -W Flush type Flange rating A4 ANSI class 600 Process connection size (Process flange size) 3 3-inch (80 mm) Flange material C 316 SST(3) Gasket contact surface(4) 1 Serration (for ANSI flange with wetted parts material SW only) Extension 0 None Fill fluid(7) -C For high temperature use (silicone oil)(8)(9) Capillary connection A Side of diaphragm seal unit 2 Always 2 Capillary length(10) 5 5 m /KF25 Material certificate /M2W Process flange, Block For Flush type Pressure test/ Leak test certificate(11)(12) /T58 ANSI/JPI Class 600(13) 16 MPa (2300 psi) Nitrogen Gas(14) The “*” marks indicate the most typical selection for each specification Material of a blind plug; aluminum alloy for code 5 and 9, and SUS304 for code 7. Not applicable for output signal code G. Forged version of the material may be used. See table 3 ‘Gasket contact surface’ on page 6. Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user’s process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and hightemperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material. When specified flushing connection ring code 1 or 2, exclusive gaskets are provided for transmitter side. Even in case where fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and dehydrating treatment for the wetted parts is required, specify option code K1 or K5. Wetted parts material code TW (Tantalum) cannot be applied. Not applicable for flashing connection ring code 1 and 2. In case of wetted parts material code HW (Hastelloy C) and TW (Tantalum) for 2-inch process flange, specify capillary length from 1 to 5m. The unit on the certificate is always MPa regardless of selection of option code D1, D3, or D4. A flushing connection ring will not be applied when conducting the pressure test or leak test. Applicable for flush type (process connection style code W.) Dry nitrogen gas is used for oil-prohibited use (option code K1 and K5.) NOTE: This item is a replacement of EJA118W-FHSA4EB-CA05-99DN/KF25/M05/T39

محصولات مشابه