ویژگی ها / Specifications
| Model | EJA118E Diaphragm Sealed Differential Pressure Transmitter |
| Others | 316L SST |
| Material | - |
| Condition | New & Original in Factory Packing |
| Certificate | KEMA 07ATEX0109 X |
| Factory Warranty | 12 Months |
| Vent/Drain plugs | - |
| Ambient temperature | –15 to 60°C |
| Applicable Standard | EN IEC 60079-0, EN 60079-1, EN 60079-31 |
| Process temperature | –30 to 180°C |
| Degree of protection | IP66/IP67 |
| Flushing connection ring(6) *0 Ring | None |
| Wetted parts material(5) SW Diaphragm | 316L SST |
Description / توضیحات
Description
The EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family. Released in 2012, it combines the ruggedness and success of the work-horse EJA-E series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa.
The EJA118E is a Differential Pressure Transmitter with remote diaphragm seals.
EJA118E features include:
±0.2% Accuracy
200 ms Response Time
Exida and TUV SIL2 / SIL3 Certified
Local Parameter Setting (LPS)
10-segment Signal Characterizer
Active Capillary Fill Fluid Density Compensation
Model and Suffix Codes
Model EJA118E Diaphragm sealed differential pressure transmitter
Output signal -F Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C31T02-01EN)
Measurement span (capsule) M 2.5 to 100 kPa (10 to 400 inH2O)
S Always S
C Always C
Cover flange bolts and nuts material C 660 SST
Installation -9 Horizontal piping type and left side high pressure
Amplifier housing 1 Cast aluminum alloy
Electrical connection 9 M20 female, two electrical connections with a blind plug(1)
Integral indicator D Digital indicator(2)
Mounting bracket N None
Process connection style -W Flush type
Flange rating J2 JIS 20K
Process connection size (Process flange size) 2 2-inch (50 mm)
Flange material B 304 SST(3)
Gasket contact surface(4) 1 Serration (for ANSI flange with wetted parts material SW only)
Extension 0 None
Fill fluid(7) -B For general use (silicone oil)
Capillary connection A Side of diaphragm seal unit
2 Always 2
Capillary length(8) 2 2 m
ATEX /KF22 ATEX Flameproof Approval(9)(10)
II 2G, 2D Ex db IIC T6...T4 Gb, Ex tb IIIC T85°C Db
Amb. Temp. (Tamb) for gas-proof:
T4; –50 to 75°C (–58 to 167°F), T5; –50 to 80°C (–58 to 176°F), T6; –50 to 75°C (–58 to 167°F)
Process Temp. for gas-proof (Tp):
T4; –50 to 120°C (–58 to 248°F), T5; –50 to 100°C (–58 to 212°F), T6; –50 to 85°C (–58 to 185°F)
Max. surface Temp. for dust-proof: T85°C (Tamb: –30 to 75°C, Tp: –30 to 85°C)(11)
The “*” marks indicate the most typical selection for each specification
Material of a blind plug; aluminum alloy for code 5 and 9, and SUS304 for code 7.
Not applicable for output signal code G.
Forged version of the material may be used.
See table 3 ‘Gasket contact surface’ on page 6.
Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user’s process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and hightemperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.
When specified flushing connection ring code 1 or 2, exclusive gaskets are provided for transmitter side.
Even in case where fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and dehydrating treatment for the wetted parts is required, specify option code K1 or K5.
In case of wetted parts material code HW (Hastelloy C) and TW (Tantalum) for 2-inch process flange, specify capillary length from 1 to 5m.
Applicable for Electrical connection code 2, 4, 7, 9, C and D.
Not applicable for output signal code Q.
Lower limit of ambient temperature is –15°C (5°F) when /HE is specified.
NOTE:
This item is a replacement of EJA118W-FMSJ2BB-AA02-99DN/KF21