ویژگی ها / Specifications


ModelEJA118E Diaphragm Sealed Differential Pressure Transmitter
Amb.Temp.–50 to 75°C(–58 to 167°F) for T4, –50 to 80°C(–58 to 176°F) for T5, –50 to 75°C(–58 to 167°F) for T6(12)
ConditionNew & Original in Factory Packing
Temp. CodeT6...T4
Certificate2014354
Factory Warranty12 Months
Max.Process Temp.T4;120°C(248°F), T5;100°C(212°F), T6; 85°C(185°F)
Applicable StandardC22.2 No. 25, C22.2 No. 30, CAN/CSA-C22.2 No. 94,
Ex d IIC T6...T4 EnclosureIP66/IP67
Primary seal failure annunciationat the zero adjustment screw
When installed in Division 2, “SEAL NOT REQUIRED” EnclosureType 4X,

Description / توضیحات


Description The EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family. Released in 2012, it combines the ruggedness and success of the work-horse EJA-E series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa. The EJA118E is a Differential Pressure Transmitter with remote diaphragm seals. EJA118E features include: ±0.2% Accuracy 200 ms Response Time Exida and TUV SIL2 / SIL3 Certified Local Parameter Setting (LPS) 10-segment Signal Characterizer Active Capillary Fill Fluid Density Compensation Model and Suffix Codes Model EJA118E Diaphragm sealed differential pressure transmitter Output signal -F Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C31T02-01EN) Measurement span (capsule) M 2.5 to 100 kPa (10 to 400 inH2O) S Always S C Always C Cover flange bolts and nuts material G 316L SST Installation -9 Horizontal piping type and left side high pressure Amplifier housing 3 Cast aluminum alloy with corrosion resistance properties(1) Electrical connection 7 1/2 NPT female, two electrical connections with a blind plug(2) Integral indicator D Digital indicator(3) Mounting bracket B 304 SST 2-inch pipe mounting, flat type (for horizontal piping) Process connection style -W Flush type Flange rating A2 ANSI class 300 Process connection size (Process flange size) 2 2-inch (50 mm) Flange material C 316 SST(4) Gasket contact surface(5) 1 Serration (for ANSI flange with wetted parts material SW only) Wetted parts material(6) SW [Diaphragm] 316L SST [Pipe] 316L SST [Others] 316L SST Flushing connection ring7) 0 [Ring] None [Vent/Drain plugs] - [Material] - Extension 0 None Fill fluid(8) -A For general use (silicone oil)(9) [Process temperature] –10 to 250°C [Ambient temperature] –10 to 60°C Capillary connection A Side of diaphragm seal unit 2 Always 2 Capillary length(10) A 10 m Canadian Standards Association (CSA) /CF1 CSA Explosionproof Approval(11) CAN/CSA-C22.2 No. 61010-1, CAN/CSA-C22.2 No. 61010-2-030, CAN/CSA-C22.2 No. 60079-0, CAN/CSA-C22.2 No. 60079-1, CAN/CSA-C22.2 No. 60529 Explosion-proof for Class I, Groups B, C and D. Dustignition-proof for Class II/III, Groups E, F and G. Process Sealing Certification Dual Seal Certified by CSA to the requirement of ANSI/ISA-12.27.01 No additional sealing required The “*” marks indicate the most typical selection for each specification Not applicable for electrical connection code 0, 5, 7, 9 and A. Material of a blind plug; aluminum alloy for code 5 and 9, and SUS304 for code 7. Not applicable for output signal code G. Forged version of the material may be used. See table 3 ‘Gasket contact surface’ on page 6. Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user’s process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and hightemperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material. When specified flushing connection ring code 1 or 2, exclusive gaskets are provided for transmitter side. Even in case where fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and dehydrating treatment for the wetted parts is required, specify option code K1 or K5. In case of wetted parts material code TW (Tantalum), the process temperature limit is –10 to 200°C. In case of wetted parts material code HW (Hastelloy C) and TW (Tantalum) for 2-inch process flange, specify capillary length from 1 to 5m. Applicable for Electrical connection code 2, 4, 7, 9, C and D. Lower limit of ambient temperature is –15°C (5°F) when /HE is specified.

محصولات مشابه