معرفی
جزيیات
خانه/ ترانسمیتر/ ترانسمیتر فشار/ Yokogawa/ EJA118E-JMSCJ-912DN-WA12A1SW00-BA25/KU22/A | Yokogawa EJA118E Diaphragm Sealed Differential Pressure Transmitter

EJA118E-JMSCJ-912DN-WA12A1SW00-BA25/KU22/A | Yokogawa EJA118E Diaphragm Sealed Differential Pressure Transmitter
به دلیل سفارشی بودن کالاها و نوسانات قیمت ارز، لطفا برای اطلاع از قیمت بروز کالا استعلام بگیرید.
ویژگی ها / Specifications
| Brand | Yokogawa |
| Model | EJA118E Diaphragm Sealed Differential Pressure Transmitter |
| Others | 316L SST |
| Material | - |
| Condition | New & Original in Factory Packing |
| Factory Warranty | 12 Months |
| Vent/Drain plugs | - |
| Allowable current | Max. 6000 A (1×40 µs), Repeating 1000 A (1×40 µs) 100 times |
| Ambient temperature | –15 to 60°C |
| Applicable Standard | EN 60079-0, EN 60079-11 |
| Process temperature | –30 to 180°C |
| Applicable Standards | IEC 61000-4-4, IEC 61000-4-5 |
| II 3G Ex ic IIC T4 Gc, Amb. Temp. | –30 to 60°C (–22 to 140°F)(10) |
| Flushing connection ring(5) *0 Ring | None |
| Wetted parts material(4) SW Diaphragm | 316L SST |
| Lightning protector A Transmitter power supply voltage | 10.5 to 32 V DC (10.5 to 30 V DC for intrinsically safe type.) |
Description / توضیحات
Description
The EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family. Released in 2012, it combines the ruggedness and success of the work-horse EJA-E series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa.
The EJA118E is a Differential Pressure Transmitter with remote diaphragm seals.
EJA118E features include:
±0.2% Accuracy
200 ms Response Time
Exida and TUV SIL2 / SIL3 Certified
Local Parameter Setting (LPS)
10-segment Signal Characterizer
Active Capillary Fill Fluid Density Compensation
Model and Suffix Codes
Model EJA118E Diaphragm sealed differential pressure transmitter
Output signal -J 4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)(1)
Measurement span (capsule) M 2.5 to 100 kPa (10 to 400 inH2O)
S Always S
C Always C
Coverflange bolts and nuts material J B7 carbon steel
Installation -9 Horizontal piping type and left side high pressure
Amplifier housing 1 Cast aluminum alloy
Electrical connection *2 1/2 NPT female, two electrical connections without blind plugs
Integral indicator D Digital indicator(2)
Mounting bracket *N None
Process connection style -W Flush type
Flange rating A1 ANSI class 150
Process connection size (Process flange size) 2 2-inch (50 mm)
Flange material A JIS S25C
Gasket contact surface(3) 1 Serration (for ANSI flange with wetted parts material SW only)
Extension 0 None
Fill fluid(6) *-B For general use (silicone oil)
Capillary connection(6) A Side of diaphragm seal unit
2 Always 2
Capillary length(7) 5 5 m
ATEX /KU22 Combined KF22, KS21 and ATEX Intrinsically safe Ex ic(8)(9)
[ATEX Intrinsically safe Ex ic]
Ui=30 V, Ci=27.6 nF, Li=0 µH
The “*” marks indicate the most typical selection for each specification
HART 5 or HART 7 is selectable. Specify upon ordering
Not applicable for output signal code G.
See table ‘Gasket contact surface’
Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user’s process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and hightemperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.
Not applicable for output signal code G.
Even in case where fill fluid code D (fluorinated oil) is selected, if degrease cleansing treatment or both degrease cleansing and dehydrating treatment for the wetted parts is required, specify option code K1 or K5.
In case of wetted parts material code HW (Hastelloy C) and TW (Tantalum) for 2-inch process flange, specify capillary length from 1 to 5m.
Not applicable for amplifier housing code 2 and 3.
316 or 316L SST. The specification is included in amplifier code 2.
Not applicable with color change option. Not applicable for amplifier housing code 2.