معرفی
جزيیات
خانه/ ترانسمیتر/ ترانسمیتر فشار/ Yokogawa/ EJA430E-DAS4G-912EB/FF1/D4/X2/A/HE | Yokogawa EJA430E Gauge Pressure Transmitter
EJA430E-DAS4G-912EB/FF1/D4/X2/A/HE | Yokogawa EJA430E Gauge Pressure Transmitter
به دلیل سفارشی بودن کالاها و نوسانات قیمت ارز، لطفا برای اطلاع از قیمت بروز کالا استعلام بگیرید.
ویژگی ها / Specifications
| Brand | Yokogawa |
| Model | EJA430E Gauge Pressure Transmitter |
| Capsule | Hastelloy C-276(3) (Diaphragm), F316L SST, 316L SST (Others) |
| Condition | New & Original in Factory Packing |
| EJA-E Series | ±3s |
| Capsule gasket | Teflon-coated 316L SST |
| Vent/Drain plug | 316 SST |
| Factory Warranty | 12 Months |
| Primary Variable | 90ms |
| Allowable current | Max. 6000 A ( 1×40 µs ), Repeating 1000 A ( 1×40 µs ) 100 times |
| Applicable Standard | FM3600, FM3615, FM3810, ANSI/NEMA 250 |
| Wetted Parts code S | 10,000 psi |
| Applicable Standards | IEC 61000-4-4, IEC 61000-4-5 |
| All other Wetted Parts | 6,800 psi |
| Lightning protector /A Transmitter power supply voltage | 10.5 to 32 V DC ( 10.5 to 30 V DC for intrinsically safe type, 9 to 32 V DC for Fieldbus communication type.) |
| Wetted parts material(1) S# Cover flange and process connector | ASTM CF-8M(2) |
| Groups E, F and G, in Hazardous locations, indoors and outdoors (Enclosure | Type 4X) |
| Fluoro-rubber O-ring /HE All O-rings of amplifier housing. Lower limit of ambient temperature | –15°C (5°F) |
Description / توضیحات
Overview
The EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family. Released in 2012, it combines the ruggedness and success of the work-horse EJA-E series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa.
The EJA430E is a traditional-mount gauge pressure transmitter in the series.
EJA430E features include:
0.055% Accuracy (0.04% Accuracy optional)
0.1% Stability per 10 years
90 ms Response Time
Exida and TUV SIL 2/3 Certified
Local Parameter Setting (LPS)
Specifications
Measurement Types
Reference Accuracy
Primary Variable:
±0.055% of Span
±0.04% of Span (with /HAC option)
Stability (All Normal Operating Conditions)
Response Time
Rangeability
Primary Variable: 100:1
Burst Pressure (Absolute)
EJA510E:
Specification Conformance
Model and Suffix Codes
Model EJA430E Gauge pressure transmitter
Output signal -D 4 to 20 mA DC with digital communication (BRAIN protocol)
Measurement span (capsule) A 0.03 to 3.5 MPa (4.3 to 500 psi)
Process connections 4 with 1/2 NPT female process connector
Bolts and nuts material G 316L SST
Installation *-9 Horizontal piping and left side high pressure
Amplifier housing 1 Cast aluminum alloy
Electrical connection 2 1/2 NPT female, two electrical connections without blind plugs
Integral indicator E Digital indicator with the range setting switch (push button)(4)
Mounting bracket *B 304 SST 2-inch pipe mounting, flat type (for horizontal piping)
Factory Mutual (FM) /FF1 FM Explosionproof Approval(5)
Explosionproof for Class I, Division 1, Groups B, C and D, Dust-ignitionproof for Class II/III, Division 1,
“FACTORY SEALED, CONDUIT SEAL NOT REQUIRED.”
Temperature class: T6, Amb. Temp.: –40 to 60°C (–40 to 140°F)
Calibration Unit(6) /D4 M calibration (kgf/cm² unit)
Painting - Coating change /X2 Anti-corrosion coating(7)(8)
The “*” marks indicate the most typical selection for each specification.
The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO 15156. Please refer to the latest standards for details. Selected materials also conform to NACE MR0103.
Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user’s process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.
Cast version of 316 SST. Equivalent to SCS14A.
Not applicable for output signal code F.
Applicable for Electrical connection code 2, 4, 7, 9, C and D.
The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option codes D1, D3, and D4.
Not applicable for amplifier housing code 2 and 3.
Not applicable with color change option.
Attachment / فایل ضمیمه
General Specifications: EJA430E
General Specifications: EJA-E Series FOUNDATION Fieldbus Communication
General Specifications: EJA-E Series HART Communication
General Specifications: EJA-E Series PROFIBUS PA Communication
User's Manual: EJA-E Series BRAIN Communication
User's Manual: EJA-E Series FOUNDATION Fieldbus Communication
DPharp BRAIN Communication Type
User's Manual: DPharp PROFIBUS PA (EJXxxxA, EJAxxxE)
Installation Manual: EJA-E and EJX-A Series