معرفی
جزيیات
خانه/ ترانسمیتر/ ترانسمیتر فشار/ Yokogawa/ EJA530A-EAS7N-02NN/D4 | Yokogawa Gauge Pressure Transmitter

EJA530A-EAS7N-02NN/D4 | Yokogawa Gauge Pressure Transmitter
به دلیل سفارشی بودن کالاها و نوسانات قیمت ارز، لطفا برای اطلاع از قیمت بروز کالا استعلام بگیرید.
ویژگی ها / Specifications
| N | Always N |
| -0 | Always 0 |
| Model | EJA530A - Gauge Pressure Transmitter |
| Output Signal | E - 4 to 20 mA DC with digital communication (HART protocol, refer to GS 01C22T01-00E) |
| Optional Codes | /D4 - Calibration Unit4- M calibration (kgf/cm² unit) |
| Product Number | EJA530A-EAS7N-02NN/D4 |
| Mounting Bracket | #N - (None) |
| Integral Indicator | #N - (None) |
| Process Connection | 7 - 1/2 NPT male |
| Electrical Connection | #2 - 1/2 NPT female, two electrical connections without blind plug |
| Wetted Parts Material1 | *S - [Process Connection] SUS316L2; [Diaphragm] Hastelloy C-2763 |
| Measurement span (capsule) | A - 10 to 200 kPa {0.1 to 2 kgf/cm²} {1.45 to 29 psi} {0.1 to 2 bar} |
Description / توضیحات
Ordering Information
The "*" marks indicate the construction materials conform to NACE material recommendations per MR01-75. For the use of SUS316 material, there may be certain limitations for pressure and temperature. Please refer to NACE standards for details.
The "#" marks indicate the most typical selection for each specification.
Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user's process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150?C [302?F] or above). Contact Yokogawa for detailed information of the wetted parts material.
SUS316L or ASTM grade 316L.
Hastelloy C-276 or ASTM N10276.
The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by Option code D1, D3 and D4.