معرفی

جزيیات

9792

EJA530E-JCH4N-02DEL/KU22/C2/M15/T07 | Yokogawa EJA530E In-Line Mount Gauge Pressure Transmitter

برند :

Yokogawa

پارت نامبر :

EJA530E-JCH4N-02DEL/KU22/C2/M15/T07

زمان تحویل:

14 هفته

به دلیل سفارشی بودن کالاها و نوسانات قیمت ارز، لطفا برای اطلاع از قیمت بروز کالا استعلام بگیرید.

ویژگی ها / Specifications


BrandYokogawa
ModelEJA530E In-Line Mount Gauge Pressure Transmitter
OthersHastelloy C-276(3)#
ConditionNew & Original in Factory Packing
DiaphragmHastelloy C-276(3)#
Retention timeone minute
Factory Warranty12 Months
Primary Variable90 msec
Failure alarm down-scaleOutput status at CPU failure and hardware error is -5%, 3.2 mA DC or less.
II 3G Ex ic IIC T4 Gc, Amb. Temp.–30 to 60°C (–22 to 140°F)(8)
Wetted parts material(2) H Process connectorHastelloy C-276(3)#
Pressure test/ Leak test certificate(12) /T07 Test Pressure10 MPa (1450 psi)(13)
Output limits and failure operation(9) /C2 NAMUR NE43 Compliant Output signal limits3.8 mA to 20.5 mA(10)

Description / توضیحات


Overview The EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family. Released in 2012, it combines the ruggedness and success of the work-horse EJA-E series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa. EJA530E's standard features include: ±0.055% Accuracy (0.04% Accuracy optional) ±0.1% Stability per 10 years 90 ms Response Time Exida and TUV SIL2/SIL3 Certified Local Parameter Setting (LPS) Specifications Measurement Types Reference Accuracy Primary Variable: ±0.055% of Span ±0.04% of Span (/HAC option) Stability (All Normal Operating Conditions) Response Time Rangeability: Primary Variable: A, B and C Capsules: 20:1 D Capsules: 10:1 Model and Suffix Codes Model EJA530E Gauge pressure transmitter Output signal -J 4 to 20 mA DC Output with digital communication (HART 5/HART 7 protocol)(1) Measurement span (capsule) C 0.5 to 10 MPa (72.5 to 1450 psi) Process connection 4 1/2 NPT female N Always N -0 Always 0 Amplifier housing 2 ASTM CF-8M stainless steel(4) Electrical connection D M20 female, two electrical connections and a 316 SST blind plug Integral indicator E Digital indicator with the range setting switch (push button)(5) Mounting bracket L 316 SST 2-inch pipe mounting ATEX /KU22 Combined KF22, KS21 and ATEX Intrinsically safe Ex ic(6)(7) [ATEX Intrinsically safe Ex ic] Applicable Standard: EN 60079-0:2012/A11:2013, EN 60079-11:2012 Ui=30 V, Ci=27.6 nF, Li=0 µH Material certificate(11) /M15 Process Connector Nitrogen(N2) Gas or Water(14) The “•” marks indicates the most typical selection for each specification. The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO 15156. Please refer to the latest standards for details. Selected materials also conform to NACE MR0103. HART 5 or HART 7 is selectable. Specify upon ordering. Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user’s process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material. Not applicable for electrical connection code 0, 5, 7 or 9. Hastelloy C-276 or ASTM N10276. Applicable for Electrical connection code 2, 4, 7, 9, C and D. Not applicable for output signal code Q. Lower limit of ambient temperature is –15°C (5°F) when /HE is specified. Applicable for output signal codes D and J. The hardware error indicates faulty amplifier or capsule. The 1 to 5 V voltage output corresponding to 4 to 20 mA current output is applied to output signal code Q which is noncompliant to NAMUR NE43. Material traceability certification, per EN 10204 3.1 B. The unit on the certificate is always kPa/MPa regardless of selection of option code D1, D3 and D4. Applicable for capsule code C. Pure nitrogen gas or pure water is used for oil-prohibited use (option codes K1 and K2).