معرفی
جزيیات
خانه/ ترانسمیتر/ ترانسمیتر فشار/ Yokogawa/ EJA530E-JCH4N-02DEL/KU22/C2/M15/T07 | Yokogawa EJA530E In-Line Mount Gauge Pressure Transmitter

EJA530E-JCH4N-02DEL/KU22/C2/M15/T07 | Yokogawa EJA530E In-Line Mount Gauge Pressure Transmitter
به دلیل سفارشی بودن کالاها و نوسانات قیمت ارز، لطفا برای اطلاع از قیمت بروز کالا استعلام بگیرید.
ویژگی ها / Specifications
| Brand | Yokogawa |
| Model | EJA530E In-Line Mount Gauge Pressure Transmitter |
| Others | Hastelloy C-276(3)# |
| Condition | New & Original in Factory Packing |
| Diaphragm | Hastelloy C-276(3)# |
| Retention time | one minute |
| Factory Warranty | 12 Months |
| Primary Variable | 90 msec |
| Failure alarm down-scale | Output status at CPU failure and hardware error is -5%, 3.2 mA DC or less. |
| II 3G Ex ic IIC T4 Gc, Amb. Temp. | –30 to 60°C (–22 to 140°F)(8) |
| Wetted parts material(2) H Process connector | Hastelloy C-276(3)# |
| Pressure test/ Leak test certificate(12) /T07 Test Pressure | 10 MPa (1450 psi)(13) |
| Output limits and failure operation(9) /C2 NAMUR NE43 Compliant Output signal limits | 3.8 mA to 20.5 mA(10) |
Description / توضیحات
Overview
The EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family. Released in 2012, it combines the ruggedness and success of the work-horse EJA-E series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa.
EJA530E's standard features include:
±0.055% Accuracy (0.04% Accuracy optional)
±0.1% Stability per 10 years
90 ms Response Time
Exida and TUV SIL2/SIL3 Certified
Local Parameter Setting (LPS)
Specifications
Measurement Types
Reference Accuracy
Primary Variable:
±0.055% of Span
±0.04% of Span (/HAC option)
Stability (All Normal Operating Conditions)
Response Time
Rangeability:
Primary Variable:
A, B and C Capsules: 20:1
D Capsules: 10:1
Model and Suffix Codes
Model EJA530E Gauge pressure transmitter
Output signal -J 4 to 20 mA DC Output with digital communication (HART 5/HART 7 protocol)(1)
Measurement span (capsule) C 0.5 to 10 MPa (72.5 to 1450 psi)
Process connection 4 1/2 NPT female
N Always N
-0 Always 0
Amplifier housing 2 ASTM CF-8M stainless steel(4)
Electrical connection D M20 female, two electrical connections and a 316 SST blind plug
Integral indicator E Digital indicator with the range setting switch (push button)(5)
Mounting bracket L 316 SST 2-inch pipe mounting
ATEX /KU22 Combined KF22, KS21 and ATEX Intrinsically safe Ex ic(6)(7)
[ATEX Intrinsically safe Ex ic]
Applicable Standard: EN 60079-0:2012/A11:2013, EN 60079-11:2012
Ui=30 V, Ci=27.6 nF, Li=0 µH
Material certificate(11) /M15 Process Connector
Nitrogen(N2) Gas or Water(14)
The “•” marks indicates the most typical selection for each specification.
The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO 15156. Please refer to the latest standards for details. Selected materials also conform to NACE MR0103.
HART 5 or HART 7 is selectable. Specify upon ordering.
Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user’s process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.
Not applicable for electrical connection code 0, 5, 7 or 9.
Hastelloy C-276 or ASTM N10276.
Applicable for Electrical connection code 2, 4, 7, 9, C and D.
Not applicable for output signal code Q.
Lower limit of ambient temperature is –15°C (5°F) when /HE is specified.
Applicable for output signal codes D and J. The hardware error indicates faulty amplifier or capsule.
The 1 to 5 V voltage output corresponding to 4 to 20 mA current output is applied to output signal code Q which is noncompliant to NAMUR NE43.
Material traceability certification, per EN 10204 3.1 B.
The unit on the certificate is always kPa/MPa regardless of selection of option code D1, D3 and D4.
Applicable for capsule code C.
Pure nitrogen gas or pure water is used for oil-prohibited use (option codes K1 and K2).
Attachment / فایل ضمیمه
General Specifications: EJA510E and EJA530E Absolute and Gauge Pressure Transmitter
General Specifications: EJA-E Series FOUNDATION Fieldbus Communication
General Specifications: EJA-E Series HART Communication
General Specifications: EJA-E Series PROFIBUS PA Communication
User's Manual: EJA-E Series BRAIN Communication
User's Manual: EJA-E Series FOUNDATION Fieldbus Communication
DPharp BRAIN Communication Type
User's Manual: DPharp PROFIBUS PA (EJXxxxA, EJAxxxE)
Installation Manual: EJA-E and EJX-A Series