معرفی

جزيیات

15407

EJA530E-JDS4N-024EL/KS21/M15/T08/HE | Yokogawa EJA530E In-Line Mount Gauge Pressure Transmitter

برند :

Yokogawa

پارت نامبر :

EJA530E-JDS4N-024EL/KS21/M15/T08/HE

زمان تحویل:

14 هفته

به دلیل سفارشی بودن کالاها و نوسانات قیمت ارز، لطفا برای اطلاع از قیمت بروز کالا استعلام بگیرید.

ویژگی ها / Specifications


BrandYokogawa
ModelEJA530E In-Line Mount Gauge Pressure Transmitter
Others316L SST#
ConditionNew & Original in Factory Packing
DiaphragmHastelloy C-276(4)#
CertificateDEKRA 11ATEX0228 X
Electrical dataUi=30 V, Ii=200 mA, Pi=0.9 W, Ci=27.6 nF, Li=0 µH
Factory Warranty12 Months
Primary Variable90 msec
Degree of protectionIP66/IP67
Amb. Temp. for EPL Db–30 to 60°C(8)
Amb. Temp. (Tamb) for EPL Ga–50 to 60°C (–58 to 140°F)
Maximum Process Temp. (Tp) for EPL Ga120°C
Wetted parts material(3) S Process connector316L SST#
Pressure test/ Leak test certificate(10) /T08 Test Pressure50 MPa (7200 psi)(11)
Fluoro-rubber O-ring /HE All O-rings of amplifier housing. Lower limit of ambient temperature–15°C (5°F)

Description / توضیحات


Overview The EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family. Released in 2012, it combines the ruggedness and success of the work-horse EJA-E series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa. EJA530E's standard features include: ±0.055% Accuracy (0.04% Accuracy optional) ±0.1% Stability per 10 years 90 ms Response Time Exida and TUV SIL2/SIL3 Certified Local Parameter Setting (LPS) Specifications Measurement Types Reference Accuracy Primary Variable: ±0.055% of Span ±0.04% of Span (/HAC option) Stability (All Normal Operating Conditions) Response Time Rangeability: Primary Variable: A, B and C Capsules: 20:1 D Capsules: 10:1 Model and Suffix Codes Model EJA530E Gauge pressure transmitter Output signal -J 4 to 20 mA DC Output with digital communication (HART 5/HART 7 protocol)(1) Measurement span (capsule) D 5 to 50 MPa (720 to 7200 psi)(2) Process connection 4 1/2 NPT female N Always N -0 Always 0 Amplifier housing 2 ASTM CF-8M stainless steel(4) Electrical connection 4 M20 female, two electrical connections without blind plugs Integral indicator E Digital indicator with the range setting switch (push button)(5) Mounting bracket L 316 SST 2-inch pipe mounting ATEX /KS21 ATEX Intrinsically safe Approval(6)(7) Applicable Standard: EN 60079-0:2012/A11:2013, EN 60079-11:2012, EN 60079-26:2007 II 1G, 2D Ex ia IIC T4 Ga, Ex ia IIIC T85°C T100°C T120°C Db Max. surface Temp. for EPL Db: T85°C (Tp: 80°C), T100°C (Tp: 100°C), T120°C (Tp: 120°C) Material certificate(9) /M15 Process Connector The “•” marks indicates the most typical selection for each specification. The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO 15156. Please refer to the latest standards for details. Selected materials also conform to NACE MR0103. HART 5 or HART 7 is selectable. Specify upon ordering. 5 to 70 MPa (720 to 10150 psi) when /HG is specified. Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user’s process fluids. Hastelloy C-276 or ASTM N10276. Not applicable for output signal code F. Applicable for Electrical connection code 2, 4, 7, 9, C and D. Not applicable for output signal code Q. Lower limit of ambient temperature is –15°C (5°F) when /HE is specified. Material traceability certification, per EN 10204 3.1 B. The unit on the certificate is always kPa/MPa regardless of selection of option code D1, D3 and D4. Applicable for capsule code D without /HG.