ویژگی ها / Specifications
| N | Always N |
| -0 | Always 0 |
| Model | EJA530E - Gauge pressure transmitter |
| Certificate | DEKRA 11ATEX0228 X |
| Output Signal | -J - 4 to 20 mA DC Output with digital communication (HART 5/ HART 7 protocol)? |
| Optional Codes | KS21 - ATEX |
| Product Number | EJA530E-JDS7N-024DL/KS21 |
| Electrical data | Ui=30 V, Ii=200 mA, Pi=0.9 W, Ci=27.6 nF, Li=0 ?H |
| Mounting bracket | L - 316 SST 2-inch pipe mounting |
| Amplifier housing | 2 - ASTM CF-8M stainless steel4 |
| Integral indicator | D - Digital indicator5 |
| Process connections | 7 - 1/2 NPT male |
| Degree of protection | IP66/IP67 |
| Amb. Temp. for EPL Db | ? to 60?C 8 |
| Electrical connection | 4 - M20 female, two electrical connections without blind plugs |
| Wetted parts material? | S - |
| Measurement span (capsule) | D - 5 to 50 MPa (720 to 7200 psi)9 |
| Amb. Temp. (Tamb) for EPL Ga | ? to 60?C (? to 140?F) |
| Maximum Process Temp. (Tp) for EPL Ga | 120?C |
Description / توضیحات
Ordering Information
[Process connector] 316L SST#;
[Diaphragm] Hastelloy C-276?#;
[Others] 316L SST#
ATEX Intrinsically safe Approval6,7
Applicable Standard: EN 60079-0:2012/A11:2013, EN 60079-11:2012, EN 60079-26:2007
II 1G, 2D Ex ia IIC T4 Ga, Ex ia IIIC T85?C T100?C T120?C Db
Max. surface Temp. for EPL Db: T85?C (Tp: 80?C), T100?C (Tp: 100?C), T120?C (Tp: 120?C)
HART 5 or HART 7 is selectable. Specify upon ordering.
Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user s process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150?C [302?F] or above). Contact Yokogawa for detailed information of the wetted parts material.
Hastelloy C-276 or ASTM N10276.
Not applicable for electrical connection code 0, 5, 7 or 9.
Not applicable for output signal code G.
Applicable for Electrical connection code 2, 4, 7, 9, C and D
Not applicable for output signal code Q.
Lower limit of ambient temperature is ??C (5?F) when /HE is specified.
5 to 70 MPa (720 to 10150 psi) when /HG is specified.
Attachment / فایل ضمیمه
General Specifications: EJA510E and EJA530E Absolute and Gauge Pressure Transmitter
General Specifications: EJA-E Series FOUNDATION Fieldbus Communication
General Specifications: EJA-E Series HART Communication
General Specifications: EJA-E Series PROFIBUS PA Communication
User's Manual: EJA-E Series BRAIN Communication
User's Manual: EJA-E Series FOUNDATION Fieldbus Communication
DPharp BRAIN Communication Type
User's Manual: DPharp PROFIBUS PA (EJXxxxA, EJAxxxE)
Installation Manual: EJA-E and EJX-A Series