معرفی

جزيیات

16098

EJX110A-ELS4G-917DB/KU22/M11/T12 | Yokogawa EJX110A Differential Pressure Transmitter

برند :

Yokogawa

پارت نامبر :

EJX110A-ELS4G-917DB/KU22/M11/T12

زمان تحویل:

16 هفته

به دلیل سفارشی بودن کالاها و نوسانات قیمت ارز، لطفا برای اطلاع از قیمت بروز کالا استعلام بگیرید.

ویژگی ها / Specifications


ModelEJX110A - Gauge Pressure Transmitter
CapsuleHastelloy C-276? (Diaphragm); F316L SST, 316L SST (Others)
Installation-9* - Horizontal piping and left side high pressure
Output signal-E - 4 to 20 mA DC with digital communication (HART 5 protocol)
Test Pressure16 MPa(2300 psi)12
Capsule gasketTeflon-coated 316L SST
Product NumberEJX110A-ELS4G-917DB/KU22/M11/T12
Vent/Drain plug316 SST
Mounting bracketB - 304 SST 2-inch pipe mounting, flat type (for horizontal piping)
Amplifier housing1 - Cast aluminum alloy
Integral indicatorD - Digital indicator5
Process connections4 - with 1/2 NPT female process connector
Electrical connection7 - M20 female, two electrical connections and a blind plug4
Material certificate9Cover flange, Process connector10
Wetted parts material?S -
Bolts and nuts materialG - 316L SST
Measurement span (capsule)L - 0.1 to 10 kPa (0.4 to 40 inH2O) (For Wetted parts material code M, H, T, A,D, B and W)
Nitrogen(N2) Gas Retention timeone minute
II 3G Ex ic IIC T4 Gc, Amb. Temp.-30 to 60?C (-22 to 140?F)8
Cover flange and process connectorASTM CF-8M?

Description / توضیحات


Yokogawa Pressure Transmitter Model and Suffix Codes Optional Codes: /KU22 Combined KF22, KS21 and ATEX Intrinsically safe Ex ic6,7 [ATEX Instrisically safe Ex ic] Applicable Standard: EN 60079-0:2012, EN 60079-11:2012 Ui=30 V, Ci=27.6 nF, Li=0 H /M11 /T12 Pressure test/Leak test certificate11 NOTE: The " * " marks indicate the most typical selection for each specification. Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the users process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150?C [302?F] or above). Contact Yokogawa for detailed information of the wetted parts material. Cast version of 316 SST. Equivalent to SCS14A. Hastelloy C-276 or ASTM N10276. Material of a blind plug is aluminum alloy or 304 SST. Not applicable for output signal code G. Applicable for Electrical connection code 2, 4, 7, 9, C and D. Not applicable for option code /AL. Lower limit of ambient temperature is 15?C (5?F) when /HE is specified. Material traceability certification, per EN 10204 3.1B. Applicable for process connections codes 1, 2, 3, and 4. Applicable for wetted parts material code S; process connection code 0 and 5; and installation code 8 and 9. Not applicable for option code U1, N2, N3 and M11. No PTFE is used for wetted parts. Applicable for capsule code F and L. Also applicable for capsule M, H and V when combined with Wetted Parts Material code H, M, T, A, D, B and W.