معرفی
جزيیات
خانه/ ترانسمیتر/ ترانسمیتر فشار/ Yokogawa/ EJX120A-FES4J-917EB/SU21/M11/T04 | Yokogawa EJX120A Differential Pressure Transmitter

EJX120A-FES4J-917EB/SU21/M11/T04 | Yokogawa EJX120A Differential Pressure Transmitter
به دلیل سفارشی بودن کالاها و نوسانات قیمت ارز، لطفا برای اطلاع از قیمت بروز کالا استعلام بگیرید.
ویژگی ها / Specifications
| Model | EJX120A - Differential pressure transmitter |
| Capsule | Hastelloy C-276? (Diaphragm); F316L SST, 316L SST (Others) |
| Amb.Temp. | ? to 75?C(? to 167?F) for T4, ? to 80?C(? to 176?F) for T5, ? to 75?C(? to 167?F) for T6 |
| Certificate | IECEx CSA 07.0008 |
| IECEx Scheme | /SU21 |
| Installation | -9 - Horizontal piping and left side high pressure |
| Output signal | -F - Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C25T02-01EN) |
| Capsule gasket | Teflon-coated 316L SST |
| Product Number | EJX120A-FES4J-917EB/SU21/M11/T04 |
| Vent/Drain plug | 316 SST |
| Mounting bracket | B - 304 SST 2-inch pipe mounting, flat type (for horizontal piping) |
| Amplifier housing | 1 - Cast aluminium alloy |
| Max.Process Temp. | T4;120?C(248?F), T5;100?C(212?F), T6; 85?C(185?F) |
| Integral indicator | E - Digital indicator with the range setting switch (push button)5 |
| Process connections | 4 - with 1/2 NPT female process connector |
| Electrical Parameters | Ui=30V,Ci=27.6 nF, Li=0 ?H |
| Electrical connection | 7 - 1/2 NPT female, two electrical connections and a blind plug4 |
| Material Certificate9 | /M11 - Cover flange, Process connector10 |
| Wetted parts material | S |
| Bolts and nuts material | J - B7 carbon steel |
| Ex ic IIC T4 Gc IP code | IP66 |
| Measurement span (capsule) | E - 0.025 to 1 kPa (0.1 to 4 inH2O) |
| Cover flange and process connector | ASTM CF-8M |
| Flameproof for Zone 1, Ex d IIC T6...T4 Gb Enclosure | IP66/IP67 |
Description / توضیحات
Ordering Information
IECEx Intrinsically safe and Flameproof Approval6,7
Intrinsically safe Ex ia
Applicable Standard: IEC 60079-0:2011, IEC 60079-11:2011, IEC 60079-26:2006 Ex ia IIC T4 Ga
Amb. Temp.: ? to 60?C(? to 140?F), Max. Process Temp.: 120?C(248?F)
Intrinsically safe Ex ic
Applicable Standard: IEC 60079-0:2011, IEC 60079-11:2011
Amb. Temp.: ? to 60?C(? to 140?F)8, Max. Process Temp.: 120?C(248?F)
Flameproof
Applicable Standard: IEC 60079-0:2011, IEC60079-1:2007-4
Pressure test/Leak test certificate11: /T04 - Test Pressure: 50 kPa (7.25 psi); Nitrogen(N?) Gas12 Retention time: one minute
The " * " marks indicate the most typical selection for each specification.
Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user s process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150?C [302?F] or above). Contact Yokogawa for detailed information of the wetted parts material.
Cast version of 316 SST. Equivalent to SCS14A.
Hastelloy C-276 or ASTM N10276.
Material of a blind plug is aluminum alloy or 304 SST.
Not applicable for output signal code F.
Applicable for Electrical connection code 2, 4, 7, 9, C and D.
Not applicable for option code /AL.
Lower limit of ambient temperature is ??C (5?F) when /HE is specified.
Material traceability certification, per EN 10204 3.1B.
Applicable for process connections codes 1, 2, 3, and 4.
The unit on the certificate is always Pa unit regardless of selection of option code D1, D3 or D4.
Pure nitrogen gas is used for oil-prohibited use (option codes K1 and K5).
Attachment / فایل ضمیمه
General Specifications - EJX120A
General Specifications - EJX-A Series HART 5 /HART 7 Communication
General Specifications - EJX-A Series FOUNDATION Fieldbus Communication
General Specifications - EJX-A Series Profibus PA Communication
EJX-A Series and EJA-E Series Explosion Protected Type and Marine Certificate Type
User's Manual - EJX-A Series BRAIN Communication
User's Manual - EJX-A Series FOUNDATION Fieldbus Communication
User's Manual - DPharp PROFIBUS PA (EJXxxxA, EJAxxxE)
Installation Manual - EJA-E and EJX-A Series