معرفی
جزيیات
خانه/ ترانسمیتر/ ترانسمیتر فشار/ Yokogawa/ EJX530A-EBS4N-019DN/KS21/D3/X2/T06/M15 | Yokogawa EJX530A Gauge Pressure Transmitter

EJX530A-EBS4N-019DN/KS21/D3/X2/T06/M15 | Yokogawa EJX530A Gauge Pressure Transmitter
به دلیل سفارشی بودن کالاها و نوسانات قیمت ارز، لطفا برای اطلاع از قیمت بروز کالا استعلام بگیرید.
ویژگی ها / Specifications
| Brand | Yokogawa |
| Model | EJX530A Gauge Pressure Transmitter |
| Others | 316L SST# |
| Condition | New & Original in Factory Packing |
| D Capsule | 19,100 psi (132 MPa) |
| Diaphragm | Hastelloy C-276(2)# |
| Certificate | DEKRA 11ATEX0228 X |
| EJX-A Series | ±3s |
| Electrical data | Ui=30 V, Ii=200 mA, Pi=0.9 W, Ci=27.6 nF, Li=0 µH |
| Factory Warranty | 12 Months |
| Primary Variable | 90ms |
| A, B, or C Capsule | 4,350 psi (30 MPa) |
| Applicable Standard | EN IEC 60079-0, EN 60079-11 |
| Degree of protection | IP66/IP67 |
| Amb. Temp. for EPL Db | –30 to 60°C(7) |
| Painting /X2 Coating change | Anti-corrosion coating(9) |
| Amb. Temp. (Tamb) for EPL Ga | –50 to 60°C (–58 to 140°F) |
| Maximum Process Temp. (Tp) for EPL Ga | 120°C |
| Wetted parts material(1) S Process connector | 316L SST# |
| Pressure test/ Leak test certificate(10)(11) /T06 Test Pressure | 2 MPa (290 psi)(12) |
Description / توضیحات
Overview
The EJX-A series is Yokogawa's premium performance line of DPharp transmitters. Released in 2004, it offers the performance and stability needed in demanding applications. The EJX-A series performance makes it the thoroughbred of the DPharp family of pressure transmitters.
The EJX530A is an In-Line Gauge Pressure Transmitter in the series.
EJX530A standard features include:
±0.04% Accuracy
±0.1% per 15 years Stability
90 ms Response Time
Exida and TUV SIL 2/3 Certified
Local Parameter Setting (LPS)
Specifications
Measurement Types
Reference Accuracy
Stability
Response Time
Rangeability
Primary Variable:
A Capsule: 25:1
B, C, or D Capsule: 50:1
Burst Pressure (Absolute)
Specification Conformance
Model and Suffix Codes
Model EJX530A Gauge pressure transmitter
Output signal -E 4 to 20 mA DC Output with digital communication (HART 5 protocol)
Measurement span (capsule) B 0.04 to 2 MPa (5.8 to 290 psi)
Process connections 4 1/2 NPT female
N Always N
-0 Always 0
Amplifier housing *1 Cast aluminum alloy
Electrical connection 9 M20 female, two electrical connections with a blind plug(3)
Integral indicator D Digital indicator(4)
Mounting bracket N None
ATEX /KS21 ATEX Intrinsically safe Approval(5)(6)
II 1 G Ex ia IIC T4 Ga, II 2 D Ex ia IIIC T85°C T100°C T120°C Db
Max. surface Temp. for EPL Db: T85°C (Tp: 80°C), T100°C (Tp: 100°C), T120°C (Tp: 120°C)
Calibration units(8) /D3 bar calibration (bar unit)
Material certificate(11)(13) /M12 Process Connector
The “*” marks indicates the most typical selection for each specification.
Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user’s process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.
Hastelloy C-276 or ASTM N10276.
Material of a blind plug; aluminum alloy for code 5 and 9, and SUS304 for code 7.
Not applicable for output signal code G.
Applicable for Electrical connection code 2, 4, 7, 9, C and D.
Not applicable for option code /AL.
Lower limit of temperature is –15°C (5°F) when /HE is specified.
The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option codes D1, D3, and D4.
Not applicable with color change option. Not applicable for amplifier housing code 2.
The unit on the certificate is always kPa/MPa regardless of selection of option code D1, D3 and D4.
Not applicable with process connections code for diaphragm seal system P.
Applicable for capsule code B.
Material traceability certification, per EN 10204 3.1 B.
The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO 15156. Please refer to the latest standards for details. Selected materials also conform to NACE MR0103.
Attachment / فایل ضمیمه
EJX Series FOUNDATION Fieldbus Communication
EJX Series HART 5/HART 7 Communication
EJX Series PROFIBUS PA Communication
EJX510A and EJX530A Absolute and Gauge Pressure Transmitter
EJX-A Series and EJA-E Series Explosion Protected Type and Marine Certificate Type
Installation Manual - EJX530A
User's Manual - EJX530A Hardware
User's Manual - EJX-A Series BRAIN Communication
User's Manual - EJX-A Series FOUNDATION Fieldbus Communication
User's Manual - EJX-A Series PROFIBUS PA Communication