معرفی
جزيیات
خانه/ ترانسمیتر/ ترانسمیتر فشار/ Yokogawa/ EJX530A-EDS7N-017DL/D1/KF22 | Yokogawa EJX530A Gauge Pressure Transmitter

EJX530A-EDS7N-017DL/D1/KF22 | Yokogawa EJX530A Gauge Pressure Transmitter
به دلیل سفارشی بودن کالاها و نوسانات قیمت ارز، لطفا برای اطلاع از قیمت بروز کالا استعلام بگیرید.
ویژگی ها / Specifications
| N | Always N |
| -0 | Always 0 |
| /D1 | Calibration units(5) - P calibration (psi unit) |
| /KF22 | ATEX |
| Model | EJX530A - Gauge pressure transmitter |
| Certificate | KEMA 07ATEX0109 X |
| Output signal | -E - 4 to 20 mA DC Output with digital communication (HART protocol) |
| Mounting bracket | L - 316 SST 2-inch pipe mounting |
| Amplifier housing | 1 - Cast aluminium alloy |
| Integral indicator | D - Digital indicator |
| Applicable Standard | EN 60079-0, EN 60079-1, EN 60079-31 |
| Process connections | 7 - 1/2 NPT male |
| Degree of protection | IP66 and IP67 |
| Electrical connection | 7 - 1/2 NPT female, two electrical connections with a blind plug(4) |
| Wetted parts material(1) | S - [Process connection] 316L SST*; [Diaphragm] Hastelloy C-276(2)* |
| Measurement span (capsule) | D - 1 to 50 MPa (145 to 7200 psi) |
| Max. process Temp. for gas-proof (Tp) | T4; 120?C (248?F), T5; 100?C (212?F), T6; 85?C (185?F) |
Description / توضیحات
Model and Suffix Codes
Optional Codes:
ATEX Flameproof Approval(6)
II 2G, 2D Ex d IIC T6...T4 Gb, Ex tb IIIC T85?C Db IP6X
Amb. Temp. (Tamb) for gas-proof:
T4; 50 to 75?C ( 58 to 167?F), T5; 50 to 80?C ( 58 to 176?F), T6; 50 to 75?C ( 58 to 167?F)
Max. surface Temp. for dust-proof: T85?C (Tamb: 30 to 75?C, Tp: 85?C)(7)
NOTE:
Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user's process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150?C [302?F] or above). Contact Yokogawa for detailed information of the wetted parts material.
Hastelloy C-276 or ASTM N10276.
Lower limit of ambient temperature is -15?C (5?F) when /HE is specified.
Material of a blind plug is aluminum alloy or 304 SST.
The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option codes D1, D3, and D4.
Applicable for Electrical connection code 2, 4, 7, 9, C and D.
Lower limit of ambient temperature is 15?C (5?F) when /HE is specified.
The * marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO 15156.
Please refer to the latest standards for details. Selected materials also conform to NACE MR0103.
Attachment / فایل ضمیمه
EJX Series FOUNDATION Fieldbus Communication
EJX Series HART 5/HART 7 Communication
EJX Series PROFIBUS PA Communication
EJX510A and EJX530A Absolute and Gauge Pressure Transmitter
EJX-A Series and EJA-E Series Explosion Protected Type and Marine Certificate Type
Installation Manual - EJX530A
User's Manual - EJX530A Hardware
User's Manual - EJX-A Series BRAIN Communication
User's Manual - EJX-A Series FOUNDATION Fieldbus Communication
User's Manual - EJX-A Series PROFIBUS PA Communication