Model Description IMV31 Multivariable Transmitter Electronics Versions and Output Signal -T Intelligent; Digital HART and 4 to 20 mA dc (Version -T) Structure Code - Process Covers, Sensor Material, and Sensor Fill Fluid Covers Sensor Fill Fluid 22 316 ss 316L ss Silicone Span Limits - Differential Pressure (DP) Measurement kPa inH2O mbar Available with (a) C 2.5 and 210 10 and 840 10 and 840 10 and 840 MPaa psia bara or kg/cm² abs Available with (a) E 0.21 and 10 (n) 30 and 1500 (n) 2.1 and 100 (n) DP Codes B and C only Process Connector Type (Material Same as Process Cover Material) 2 1/2 NPT Conduit Connection and Housing Material 1 1/2 NPT Connection, Aluminum Housing Electrical Safety F FM approved Division 1 intrinsically safe, explosionproof, dust-ignitionproof, and nonincendive, Division 2, Classes I, II, and III. ALso zone approved instrinsically safe AEx ia IIC. Mounting Bracket Set -M2 Stainless Steel Bracket with Stainless Steel Bolts Bolting for Process Covers/Connectors (b) B1 316 ss Bolts and Nuts Custom Factory Configuration C2 Full Factory Configuration (Requires completion of Multivariable Configuration Wizard before entering the order) (c) Digital Indicator with Pushbuttons L1 Digital Indicator, Pushbuttons, and Window Cover (a) Refer to Functional Specifications section for allowable combinations of DP and AP Span Limit Codes. (b) Not available with DIN 19213 Construction options. For stainless steel bolting with DIN 19213, specify -D5, -D6, -D7, or -D8. (c) IPS recommends the selection of Option -C2 if the application information is known. If Option -C2 is not selected, a standard default configuration will be provided. The user will then need the Model PCMV to completely configure the transmitter for liquid level applications.