معرفی
جزيیات
خانه/ تجهیزات اندازه گیری/ اندازه گیری دبی/ Yokogawa/ RAMC05-A1SS-72V5-T91NNN/K3/BG/KS1/A13 | Yokogawa RAMC05 Metal Short Stroke Rotameter

RAMC05-A1SS-72V5-T91NNN/K3/BG/KS1/A13 | Yokogawa RAMC05 Metal Short Stroke Rotameter
به دلیل سفارشی بودن کالاها و نوسانات قیمت ارز، لطفا برای اطلاع از قیمت بروز کالا استعلام بگیرید.
ویژگی ها / Specifications
| NOTE | Replacement of RAMC05-A1SS-72V5-T65*NNNB/K3/BG/XE*/A13 |
| Model | RAMC05 Metal Short Stroke Rotameter |
| Flow range air | 0.075 to 1400 m³/h (+20 °C, 1.013 bar abs) |
| Product Number | RAMC05-A1SS-72V5-T91NNN/K3/BG/KS1/A13 |
| Flow range water | 0.0025 to 130 m³/h |
| Dust explosion proof | ATEX, IECEx, NEPSI, TS |
| Ex for non-electrical RAMC | ATEX, EAC |
| Flame proof version (Ex d) | ATEX, IECEx, NEPSI, PESO, KOSHA, EAC, TS |
| Intrinsically safe version (Ex i) | ATEX, IECEx, FM (C/US), NEPSI, PESO, EAC |
Description / توضیحات
Description
The short-tube Rotameter is used for measurement of flow rates of liquids and gases. Its special application is in turbulent, opaque or aggressive fluids. The instrument is mounted in a vertical pipeline with flow direction upwards. Inside the special shaped conical metal tube, a float is guided concentrically. The position of this float is magnetically transmitted to the indicator. The indicators are exchangeable without influencing the accuracy.
Features
Different process connections like flanges according to EN and ASME
All wetted parts in stainless steel or PTFE
Measuring accuracy acc. standard VDI/VDE 3513 sheet 2 (qG = 50 %) at calibration conditions
Float damping to avoid float bouncing with gas applications
Optional heat tracing (with steam or fluid heat carrier)
Indicator in steel or aluminum, protection class IP66/67
Mechanical indicator without additional power supply
Microprocessor controlled transmitter with 24 V, 115 V or 230 V power supply
FMEDA report available for SIL application
Limit switches, also available as “fail-safe” version
Electronic transmitter as standard with digital display with the following features:
- Flow indication (totalizer, actual, percent)
- Indication of different volume- and mass flow units
- Possibility of user calibration in the field
- Float blocking indication function
- Adjustable signal output damping
- Error message indication
- Temperature measurement in the electronic transmitter
- HART® 5/7-Communication