| Tag | 1 = One Wired Stainless Steel Tag (Up to 4 lines 26 char/line) Unassembled |
| URL | 400/(1000) LRL -400/(-1000) Max Span 400/(1000) Min Span 1.0 (2.5) Units " H2O (mbar)Process |
| Type | C Material Polyester Powder Coated Aluminum Connection 1/2 NPT Lightning Protection Yes Output/ |
| Bracket | 0 Bracket Type None Material None Customer |
| Adapters | A6 = 1/2 NPT 316 SS Certified Conduit Plug Certifications & |
| Pressure | S = Standard Static Pressure - 4500 psig (310 bar) except STD810 50 psi (3.5 bar) Head/Connect |
| Protocol | F Analog Output None Digital Protocol Foundation Fieldbus Customer |
| Settings | 5 Write Protect Enabled Fail Mode N/A High & Low Output Limits N/A & Fieldbus or Profibus General |
| Software | 1 = Standard Diagnostics Output Limit, |
| Warranty | F1 = Calibration Test Report & Certificate of Conformance (F3399) |
| Connection | H Process Head Material 1/2" NPT female Diaphragm Material Materials to Match Head & Head Bolt Materials Selections Bolt/Nut |
| Selections | B Indicator Basic Ext Zero, Span & Config Buttons None Languages English Application |
| Calibration | A Accuracy StandardCalibrated Range Factory Std Calibration Qty Single CalibrationMounting |
| Orientation | 1 = Standard, High Side Left, Low Side Right / Std Head Orientation Approvals A = FM Explosion proof, Intrinsically Safe, Non-incendive, & Dustproof Electronic |
| Configuration | S = Factory Standard Accuracy |
| Type/Location | 4 Head Type Dual Ended Vent Type Standard Vent Location Matches Head Material Gasket |