معرفی
جزيیات
خانه/ ترانسمیتر/ ترانسمیتر فشار/ Honeywell/ STR82D-21CC1C0-AFCAA21BS-A-BHS-11C-B-11A0-F1,F5 | Honeywell STR82D SmartLine Pressure Transmitter with Remote Diaphragm Seals

STR82D-21CC1C0-AFCAA21BS-A-BHS-11C-B-11A0-F1,F5 | Honeywell STR82D SmartLine Pressure Transmitter with Remote Diaphragm Seals
به دلیل سفارشی بودن کالاها و نوسانات قیمت ارز، لطفا برای اطلاع از قیمت بروز کالا استعلام بگیرید.
ویژگی ها / Specifications
| Model | STR82D SmartLine Pressure Transmitter with Remote Diaphragm Seals |
| Buttons | Yes |
| Material | Carbon Steel |
| Condition | New & Original in Factory Packing |
| Fail Mode | High> 21.0mAdc |
| Languages | English |
| Connection | M20 |
| Flange Size | 3" |
| Upper Insert | 316L SS |
| Calibration Qty | Single Calibration |
| Calibrated Range | Custom (Unit Data Required) |
| Digital Protocol | HART Protocol |
| Factory Warranty | 12 Months |
| Lightning Protection | None |
| Flange Pressure Rating(1) | ANSI 300 |
| High & Low Output Limits(3) | Honeywell Std (3.8 - 20.8 mAdc) |
| Wetted Material AA Diaphragm | 316L SS |
| Mounting Bracket 1 Bracket Type | Angle Bracket |
| Output/ Protocol H Analog Output | 4-20mA dc |
| Accuracy and Calibration B Accuracy | Standard |
| Customer Interface Selections S Indicator | Basic |
| Flush Flanged Seal with Lower** AFC Diaphragm Diameter | 3.5" |
| Electronic Housing Material & Connection Type B Material | Polyester Powder Coated Aluminum |
| Connection of Remote Seal to Meter Body** C Capillary Length | 15 feet (4.5 m), SS Armor |
| Output Limit, Failsafe & Write Protect Settings 1 Write Protect | Disabled |
Description / توضیحات
Ordering Information
Model STR82D SmartLine Pressure Transmitter with Remote Diaphragm Seals
Number of Seals 2 2 Remote Seals
Primary Fill Fluid (Meter body) 1 Silicone Oil 200
Dual Head DP C 316 SS (bolt-on heads)
Bolts and Nuts for Transmitter Heads C Carbon Steel Bolts and Nuts
Secondary Fill Fluid (capillary & seal)** 1 Silicone Oil 200
Seal Option** 0 None
Non-Wetted Material (upper, upper insert) 2 316L SS
Seal-Capillary Connection 1 Center Seal
Calibration Rings B 316L SS
Flushing Connection and Plugs(2) S Two 1/2" with metal plugs
Approvals A FM Explosion proof, Intrinsically Safe, Non-incendive, & Dustproof
Application Software 1 Standard Diagnostics
General Configuration C Custom Configuration (Unit Data Required from customer)
Customer Tag 1 One Wired Stainless Steel Tag (Up to 4 lines 26 char/line)
Unassembled Conduit Plugs & Adapters A0 No Conduit Plugs or Adapters Required
Certifications & Warranty F1
F5 Calibration Test Report & Certificate of Conformance (F3399)
Certificate of Origin (F0195)
** Refer to 34-ST-00-128 for additional options, consult factory
Standard facing 125-250 AARH RF (raised face) serrated surface finish.
Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation.
NAMUR Output Limits 3.8 - 20.5mAdc can be configured by the customer or select custom configuration Table Vc.