معرفی
جزيیات
خانه/ سایر/ Honeywell/ STT840-25H-TC,TG,EM,A1,W1,CD,CC-EPEE-H06S-R2UD-BRR15C10080-2K-TMC,PT2,HT1 | Honeywell Flanged Bar Stock Thermowell Assembly

STT840-25H-TC,TG,EM,A1,W1,CD,CC-EPEE-H06S-R2UD-BRR15C10080-2K-TMC,PT2,HT1 | Honeywell Flanged Bar Stock Thermowell Assembly
برند :
پارت نامبر :
STT840-25H-TC,TG,EM,A1,W1,CD,CC-EPEE-H06S-R2UD-BRR15C10080-2K-TMC,PT2,HT1
زمان تحویل:
18 هفته
به دلیل سفارشی بودن کالاها و نوسانات قیمت ارز، لطفا برای اطلاع از قیمت بروز کالا استعلام بگیرید.
ویژگی ها / Specifications
| ID | 0.385 |
| 17X | 1, 3, H, F |
| 25X | H, M, D, T |
| 35X | 0, F |
| OD-1 | 0.75 |
| OD-2 | 0.88 |
| Size | 1.5 in. |
| Brand | Honeywell |
| Model | Flanged Bar Stock Thermowell Assembly |
| Union | SS |
| Nipple | Stn. Stl. |
| Rating | 600 lbs |
| Table I | 0TB,17_,25_ - 6" Lead length |
| A Length | 5 in. |
| Material | Carbon Steel, 304 or 316 Stn. Stl. |
| 0 Decimal | .00 in. or No sensor |
| Condition | New & Original in Factory Packing |
| Flameproof | Ex d IIC, T*** |
| Environmental | NEMA 4X/IP66**** |
| Explosion-Proof | Class I, Div. 1, Groups B,C,D |
| Factory Warranty | 12 Months |
| Dust Ignition-Proof | Class III, Div. 1 T*** |
| Process Connection R15C Type | Raised Face |
Description / توضیحات
Ordering Information
Model STT840 Flanged Bar Stock Thermowell Assembly
Transmitter Selection 25H Wired to STT25H (HART)
Configuration TC Transmitter Configuration
Customer Tagging TG 316 SS Wired-on Customer I.D. Tag (4 lines, 28 chars.)
Owners Manual (Transmitter) EM STT250 English Language Version
316 SS Conduit Adaptors A1 1/2 NPT to M20 - CSA CL I, Div 1, GP ABCD, Type 4; ATEX, IECEx, Ex d IIC, IP66 - 1 Adaptor
Warranty W1 Additional Transmitter Warranty - 1 year
Optional Certificate CD
CC Factory Transmitter Configuration/ Calibration Certificate
Certificate of Conformance/ Origin
Field-mount Honeywell Housings EPE Aluminum explosion proof with Beige Epoxy Coating
Integral Meter E E.U. Meter for Field Mount Housing
Extension Type H06S Hex nipple-union-nipple
Sensor Type R2 RTD Applications (-58 to +500oF)
1 x Pt100 (IEC), 3-wire
Sensor Grounding U Ungrounded(standard for RTDs but also applicable for TCs)
Lead Length D Factory Defaults : Table V : 000D - No Lead length
Well Design B Tapered
Well & Flange Material R 316 Stainless Steel
Lag 10 2.75 in.
Insertion Length "U" 08 8 in.
Safety Approvals 2K CSA
Assembly Options TMC
PT2
HT1 Thermowell material certificate
External hydrostatic pressure test of thermowell (2500 PSI Standard) (4)
NACE certificate (applies to Well)
*** Temperature Class (T-Codes) is T6 with terminal block or dependant on transmitter.
**** Type 4X and IP66 ratings are dependent upon the enclosure, nipple extension and thermowell materials. IP66 dependent upon enclosure and a thermowell is required.