Description / توضیحات


Features

  • Measures differential pressure, flow velocity & volume
  • Automatic zero-point adjustment
  • Display and optical alarm
  • Plastic housing
  • Ethernet, relay and analog outputs
  • High system stability with transmitter self-monitoring and early warning function
  • P2A software available for setting/adjusting parameters and data analysis
  • Scalability of ±50% of the measuring range value and free scalability within the measuring range

The Testo 6351 differential pressure transmitter measures differential pressure, flow velocity and flow volume. The Testo 6351 has a measurement range of 50 Pa to 2000 hPa and automatic zero-point adjustment which guarantees high, temperature-independent accuracy and long-term stability. The Testo 6351 differential pressure transmitter has many features including Ethernet, relay and analog outputs to allow optimum integration into existing automation systems. A display for easy adjustments via the operating menu and an optical alarm. The 6351 is compatible with P2A software which allows for the parameterization of unit and scale, sensor adjustment, analog output adjustment and adjustment history which can all be transferred to a PC for data storage and analysis. The self-monitoring transmitters guarantee high system availability. Applications for the Testo 6351 Differential Pressure Transmitter Differential pressure monitoring between cleanrooms Differential pressure monitoring in filling processes and spray-painting systems Monitoring differential pressure, flow volume and velocity in critical air conditioning technology (VAC systems) Testo 6351 Differential Pressure Transmitter Specifications Differential Pressure Parameters Measuring Range 0 to 50 Pa0 to 100 Pa0 to 500 Pa0 to 10 hPa0 to 50 hPa0 to 100 hPa0 to 500 hPa0 to 1000 hPa0 to 2000 hPa -50 to 50 Pa-100 to 100 Pa-500 to 500 Pa-10 to 10 hPa-50 to 50 hPa-100 to 100 hPa-500 to 500 hPa-1000 to 1000 hPa-2000 to 2000 hPa Measurement Uncertainty ±0.8% of measurement range final value ±0.3 Pa Selectable Units Pa,more available Sensor Piezoresistive sensor Automatic Zero-point adjustment Via magnetic valve. Frequency settable: 15 sec, 30 sec, 1 min, 5 min, 10 min Overload Measuring Range:0 to 50 Pa0 to 100 Pa0 to 500 Pa0 to 10 hPa0 to 50 hPa0 to 100 hPa0 to 500 hPa0 to 1000 hPa0 to 2000 hPa-50 to 50 Pa-100 to 100 Pa-500 to 500 Pa-10 to 10 hPa-50 to 50 hPa -100 to 100 hPa-500 to 500 hPa-1000 to 1000 hPa Overload:20000 Pa20000 Pa20000 Pa20000 Pa200 hPa750 hPa750 hPa2500 hPa2500 hPa20000 Pa20000 Pa20000 Pa20000 Pa200 hPa750 hPa750 hPa2500 hPa2500 hPa Analog Outputs Qunatity 1 Output type 0/4 to 20 mA (4-wire) (24 VAC/DC)0 to 1/5 to 10 V (4-wire)(24 VAC/DC) Measuring Cycle 1/sec Resolution 12 bit Scaling Differential pressure: scalable ±50 % of measuring range final value; freely scalable within measuring range Load max. 500 Ω Other Outputs Ethernet Optional with Ethernet module Relay Optional: 4 relays (free allocation to measurement channels or as collective alarm in operating menu/P2A software), up to 250 VAC/3A (NO or NC) Digital output Mini-DIN for P2A software Supply Voltage Supply 20 to 30 VAC/DC, 300 mA current consumption, galvanically separate signal and supply line