ویژگی ها / Specifications


ATEX/KU2
ModelYTA610 - Temperature Transmitter
EnclosureIP66/IP67
CertificateKEMA 07ATEX0130
Housing CodeA - Aluminum
Sensor Input1 - Single
Output SignalJ - 4 to 20 mA DC with digital communication HART 7 protocol
Sensor circuitUo=6V, Io=90mA, Po=135mW, Co=10µF, Lo=3.9mH
Mounting BracketD - SUS304 stainless steel 2-inch vertical pipe mounting bracket
Integral IndicatorD - Digital indicator with Local Operating Switch
Ambient Temperature-40 to 70°C for T4, -40 to 50°C for T5
Dielectric strength500 V a.c.r.m.s, 1 min
Electrical Connection1/2 NPT female and M20 female³
Supply/Output circuitUi=30V, li=200mA, Pi=1.0W, Ci=22nF, Li=0mH
Ambient Temperature for Gas Atmospheres-40 to 75°C for T6, -40 to 80°C for T5
Ambient Temperature for Dust Atmospheres-30 to 65°C for T70°C, -30 to 80°C for T90°C

Description / توضیحات


Description The YTA610 provides high accuracy, stability, and reliability. The housing structure adopts reliable dual-compartment structure. The sensor input can be choice of single or dual inputs. This input can accept the RTD, thermocouple, ohm, or DC millivolt. It converts the sensor input to a 4 to 20 mA DC analog signal or Fieldbus digital signal. HART 7 Protocol or FOUNDATION™ Fieldbus ITK 6 version are available. The dual input can accept two sensors calculation of the differential or average value and the sensor backup function. Sensor backup functions for automatically switches-over from the primary to the backup upon sensor failure. By adoption of local parameter switch on the Indicator, it becomes easy to do the on-site setting work. YTA610 features include: Dual-compartment field-mount housing Choice of HART 7, or FOUNDATION Fieldbus ITK 6 Protocol Local Parameter Setting function (Indicator model) Basic diagnosis Ordering Information A - Always A 4-20 mA: [Intrinsically safe approval] Applicable Standard: EN 60079-0: 2012+A11:2013, EN 60079-11: 2012 Certificate No. FM16ATEX0019X II 1 G Ex ia IIC T5...T4 Ga Entity Parameters: [+, -, C, 1, 2, 3, 4, 5] to Earth terminal [+, -, C] to [1, 2, 3, 4, 5] [Flameproof and Dust Ignition Proof Approval] Applicable Standard: EN 60079-0:2012+A11:2013, EN 60079-1:2014, EN 60079-31:2014 II 2 G Ex db IIC T6/T5 Gb, II 2 D Ex tb IIIC T70°C/T90°C Db For flat-panel mounting, please prepare bolts and nuts. Not applicable for Fieldbus type. Applicable for Electrical Connection Code 2 and 4.