معرفی
جزيیات
خانه/ ترانسمیتر/ ترانسمیتر دما/ Yokogawa/ YTA710-FA2A2DB/KF2 | Yokogawa YTA710 Temperature Transmitter

YTA710-FA2A2DB/KF2 | Yokogawa YTA710 Temperature Transmitter
به دلیل سفارشی بودن کالاها و نوسانات قیمت ارز، لطفا برای اطلاع از قیمت بروز کالا استعلام بگیرید.
ویژگی ها / Specifications
| NOTE | This item is a replacement of YTA320-FA2DB/KF2 |
| Brand | Yokogawa |
| Model | YTA710 Temperature Transmitter |
| Condition | New & Original in Factory Packing |
| Enclosure | IP66/IP67 |
| Certificate | KEMA 07ATEX0130X |
| Factory Warranty | 12 Months |
| Applicable Standard | EN IEC 60079-0, EN 60079-1, EN 60079-31 |
| Electrical Connection | 1/2 NPT female and M20 female(2) |
| ATEX /KF2 [4-20mA & Fieldbus | Flameproof and dust ignition proof approval] |
| Ambient Temperature for Gas Atmospheres | –40 to 75°C for T6, –40 to 80°C for T5 |
| Ambient Temperature for Dust Atmospheres | –30 to 65°C for T70°C, –30 to 80°C for T90°C |
Description / توضیحات
Overview
The YTA710 provides high accuracy, stability, and reliability. The housing structure adopts reliable dual-compartment structure. The sensor input can be choice of single or dual inputs. This input can accept the RTD, thermocouple, ohm, or DC millivolt. It converts the sensor input to a 4 to 20mA DC analog signal or Fieldbus digital signal. HART 7 Protocol, BRAIN Protocol or FOUNDATION™ Fieldbus ITK 6 version are available. The dual input can accept two sensors calculation of the differential or average value and the sensor backup function. Sensor backup functions for automatically switches-over from the primary to the backup upon sensor failure.
By adoption of local parameter switch on the Indicator, it becomes easy to do the on-site setting work.
YTA710 features include:
Dual-compartment field-mount housing
Choice of HART 7, BRAIN Protocol or FOUNDATION Fieldbus ITK 6 Protocol
Local Parameter Setting function (Indicator model)
Advanced diagnosis
Ordering Information
Model YTA710 Temperature Transmitter
Output signal -F Digital communication (FOUNDATION Fieldbus protocol)
A Always A (Global)
Sensor input 2 Double
Housing code A Aluminum
Electrical connection 2 1/2 NPT female
Integral indicator D Digital indicator with Local Operating Switch
Mounting bracket B 304 SST or ASTM304L stainless steel 2-inch horizontal pipe mounting bracket(1)
II 2 G Ex db IIC T6/T5 Gb, II 2 D Ex tb IIIC T70°C/T90°C Db
For flat-panel mounting, please prepare bolts and nuts.
Applicable for Electrical Connection Code 2 and 4.